The MC608 A/B converter has been designed with the purpose of meeting all the requirements of modern water management systems. The converters MC608 A/B are compatible with all EUROMAG INTERNATIONAL sensors.
General Features
| Power supply MC608A |
90...264 Vac 12/24 Vac/dc |
| Power supply MC608B |
Battery powered supply or 12/24 Vac/dc Expected life T=0 / 50°C ( 32 / 122 °F) Internal battery pack » 3-6 anni Internal and external battery pack » 6-10 anni |
| Display |
Graphic LCD 128x64 pixels, 50x25mm visual area. Backlit white colour, programmable backlighting. Simultaneous display of a counter + instant variable + status flags. Counters with 8 mm high charachters for reliable and easy reading.Programmable display content.
|
| Keyboard |
yes |
| Programming mode |
menù |
| Signals in output |
- Active analogue output 4-20 mA (requiring external 24 V DC power);
- Digital output1000 Hz duty cycle max 50% for instant load, positive only, positive and negative;
- Programmable digital output for:
- Maximum pulses output for 1000 Hz duty cycle max 50% for negative load
- Negative load indication;
- Cumulative alarm
- Digital output in active frequency 0-10 kHz (requiring external 24 VDC power);
All outputs are optoisolated. Pulse outputs with a maximum capacity of ±35 V DC 50 mA. |
| Serial Communication |
- IrDA interface for communicating with laptop or hand held communicator, and dedicated SW for programming, displaying and downloading data.
- MODBUS RTU interface on RS 485.
|
| Temperature range |
Process » -10°C a 70°C Ambient » -20°C a 60°C Storage » -30°C a 70°C |
| Accuracy |
0.2% of the read value minimum2.0 mm/s |
| Repeatability |
0.1% of the read value minimum 2.0 mm/s |
| Calibration |
Standard Generic use in water » 0.4 % High performance application » 0.2% |
| Measuring stabilization time |
3s |
| Degree of protection |
IP 67/68 |
| Sampling frequency |
Programmable 5, 3, 1, 1/15, 1/30, 1/60, 1/120, 1/240, 1/480 Hz. |
|
Converter MC308C is part of the family of standard electronics available for all water cycle and process applications. It may be used with any EUROMAG INTERNATIONAL electromagnetic flow sensor
General features
| Display, 2 lines, 16 charachters |
yes |
| Keypad |
yes |
| Programming mode |
menù |
| Connector for TRM100 (hand held terminal) |
- |
| Pulses output/freq. (isolated) |
yes, open collector. |
| Alarm output (isolated) |
yes, open collector. |
| Analogical output (4-20mA) isolated |
yes |
| Second alarm output (hardware alarm) |
- |
| Digital output RS-485 |
yes, isolated |
| Universal empty pipe detenction |
yes |
| Digital input |
yes |
| Metallic housing |
yes
|
| Plastic housing |
- |
| Protection degree |
IP68 |
| Installation |
compact or separate
|
| Measurement frequency |
10/20 hz man/auto |
|
EUROMAG INTERNATIONAL Converters Series MC308 represent the standard electronics available for all water cycle and process applications. It may be used with any EUROMAG INTERNATIONAL electromagnetic flow sensor.
General features
| Display 2 lines 16 charachters |
yes |
| Keypad |
yes |
| Programming mode |
menù |
| Connector for TRM100 (hand held terminal) |
yes |
| Pulses output/freq (isolated) |
yes, open collector. |
| Alarm output (isolated) |
yes, open collector. |
| Analogical output (4-20 mA) (isolated) |
yes |
| Second alarm output (hardware alarm) |
- |
| Digital output RS-485 |
yes, not isolated |
| Universal empty pipe detenction |
optional |
| Digital input |
yes |
| Metallic housing |
aluminium
|
| Plastic housing |
yes |
| Protection degree |
IP67 |
| Installation |
compact or separate
|
| Measurement frequency |
10/20 hz man/auto |
|
The Euromag International converter MC108 represents the most versatile electronics of the highest performance, able to satisfy all of the most difficult applications. They can be connected to any electromagnetic sensor manufactured by EUROMAG INTERNATIONAL.
General features
| Display, 2 lines 16 charachters |
yes |
| Keypad |
yes |
| Programming mode |
list of numbered functions
|
| Connector for TRM100 (hand held terminal) |
yes |
| Pulses output/freq. isolated |
yes, open collector. |
| Alarm output (isolated) |
yes, open collector. |
| Analogical output (4-20 mA)(isolated) |
yes |
| Second alarm output (hardware alarm) |
- |
| Digital output RS-485 |
yes, not isolated |
| Universal empty pipe detenction |
- |
| Digital input |
yes |
| Metallic housing |
aluminium
|
| Plastic housing |
- |
| Protection degree |
IP67 |
| Installation |
Compact or separate
|
| Measurement frequency |
12.5/25/50 hz 15/30/60 hz man/auto |
|
|
The MC106 series of Euromag International converter has essential and economic charachteristics especially where a single output measurement signal is required. Other unrequired functions would increase cost and dimensions. It is applicable to all "full board" electromagnetic sensors manufactured by EUROMAG INTERNATIONAL
General features
| Display (2 lines 16 charachters) |
yes |
| Keypad |
yes |
| Programming mode |
list of numbered functions |
| Connector for TRM100 (hand held terminal) |
- |
| Pulses output/freq.(isolated) 24 Vdc |
yes, only with one output chosen beetween two options. The output is an open collector. |
| Alarm output (isolated) |
| Analogical output (4-20 mA) (isolated) |
yes |
| Second alarm output (hardware alarm) |
yes |
| Digital output RS-485 |
yes, not isolated |
| Universal empty pipe detenction |
- |
| Digital input |
- |
| Metallic housing |
- |
| Plastic housing |
yes |
| Protection degree |
IP44 |
| Installation |
separate panel mount
|
| Measurement frequency |
10/20 hz man/auto |
|
|
|
The MC106 series of EUROMAG INTERNATIONAL converter has essential and economic charachteristic, especially where a single output measurement is required. Other unrequired functions would increase costs and dimensions.It is applicable to all "full board" electromagnetic sensors manufactured by EUROMAG INTERNATIONAL.
General features
| Display 2 lines 16 charachters |
optional |
| Keyboard |
- |
| Programming mode |
List of numbered functions |
| Connector for TRM100 (hand held programmer) |
yes |
| Pulses output/freq isolated |
yes, only with output chosen beetween two options. The output is an open collector. |
| Alarm output isolated |
| Analogical output (4-20mA) isolated |
yes |
| Second alarm output (hardware alarm) |
yes |
| Digital output RS-485 |
yes, not isolated |
| Universal empty pipe detenction |
- |
| Digital input |
- |
| Metallic housing |
- |
| Plastic housing |
si |
| Protection degree |
IP67 |
| Installation |
compact or separated |
| Measurement frequency |
10/20 hz man/auto |
|
|
|
|
|
|
|
|